Powerwall 3 Operating Temperature Range

Powerwall is rated to operate in temperatures from -20°C to 50°C (-4°F to 122°F).
  • For locations where temperatures regularly drop below -20°C (-4°F), Powerwall should be installed indoors.
  • For locations where temperatures regularly exceed 40°C (104°F), Tesla recommends installing Powerwall out of direct sunlight, as full sun exposure raises the temperature inside the enclosure above ambient levels. In such locations, install the Powerwall indoors, or in case of outdoor installations, install in a shaded area with good ventilation.

Expected Powerwall Behavior Based on Ambient Temperature

Ambient Temperature Range* Solar Performance Battery Performance
Below 10°C (< 50°F)

Up to 16.5 kW solar production capacity available when on-grid**
Up to 20kW solar production capacity available when off-grid, if installed with 80A breaker and appropriately sized conductors**

Heat mode maintains battery temperature to enable normal operation up to rated power with full charging and discharging capabilities
10°C to 25°C (50°F to 77°F) Normal operation up to rated power with full charging and discharging capabilities
25°C to 40°C (77°F to 104°F) Up to 16.5 kW solar production capacity available both on-grid and off-grid**
40°C to 50°C (104°F to 122°F) Solar production continues to operate but may be limited Battery charging and discharging power may be reduced

*Ambient temperature in shaded conditions

**16.5 kW and 20 kW solar production capacity available when Powerwall 3 is charging at 5 kW in addition to producing solar at maximum capacity.