Voltage and Wiring |
Nominal 200-240 V AC
single-phase
|
Current Output Range |
12 – 48 amps |
Terminal Blocks |
12-4 AWG (3.5 - 25 mm2),
copper only |
Supported Conduit Sizing |
¾ in (21 mm) default,
1 in (27 mm) optional
|
Grounding Scheme |
TN/TT |
Frequency |
50/60 Hz
|
Cable Length |
7.3m (24ft) |
Wall Connector Dimensions |
Height: 13.6 in (345 mm)
Width: 6.1 in (155 mm)
Depth: 4.3 in (110 mm)
|
Wire Box Bracket Dimensions |
Height: 9.8 in (250 mm)
Width: 4.7 in (120 mm)
Depth: 2.0 in (50 mm)
|
Weight (including wirebox) |
10 lb. (4.5
kg)
|
Operating Temperature |
-22˚F to 122˚F (-30˚C
to 50˚C)
|
Storage Temperature |
-40˚F to 185˚F (-40˚C
to 85˚C)
|
Enclosure Rating |
Type 3R IP54 |
Ventilation |
Not required |
Means of Disconnect |
External branch circuit breaker |
Ground Fault Circuit Interrupter |
Integrated CCID20 |
Wi-Fi
|
2.4 GHz,
802.11b/g/n
|
Agency Approvals |
cULus - E351001
|
Transportation and storage: Ensure that Wall Connector is within storage temperature
when moving, transporting, or storing.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.