Optional: Dynamic Power Management
Dynamic Power Management enables Wall Connector to dynamically adjust EV charging power based on
live readings of the overall load in the panel. An energy meter is installed to MONITOR
live current in the panel; when panel loads are reduced, Wall Connector is able to
increase charging current up to a limit set by the installer.
Note
As described in the Wall Connector Application Note on Dynamic Power
Management, Wall Connector should be installed with a 60A circuit breaker
for maximum power output; if there is not enough room for a 60A breaker in the
electrical panel, a smaller breaker can be installed with a lower amperage
configuration (see the application note for more information).
- Once connected, the Remote Energy
Meter will automatically be detected. Select Meter to
configure CTs and set the Max Conductor Limit.NoteThe Remote Energy Meter has four CT ports, with the following voltage references:
- CT1: L1
- CT2: L2
- CT3: L2
- CT4: L1
- Select the Neurio meter to configure the CTs.
- For each of the connected CTs, select the CT and set the Location to Conductor.
- On the Meter screen, set
the Max Conductor
Limit. This value should be 80% of the electrical panel’s rated limit.
See the Wall Connector Application Note on Dynamic Power Management for instructions to test the system and troubleshoot as needed.