Replacing the Tube Foot
Tools and Equipment
-
Cut-resistant gloves (ANSI Cut Level 3 or EN 388
Level C)
- 4 mm Allen wrench
- 10 mm open ended / box wrench
Procedure
- Using a 4 mm Allen wrench and an 10 mm open ended / box wrench:
- Remove the (4x) M6 washers and (2x) M6 lock nuts securing the (2x) M6 x 60 mm
button head cap screws.
- Remove the (2x) M6 x 60 mm button head cap screws holding the tube foot in
place.

- Remove the tube foot from the lower tube assembly.

- Slide a new tube foot onto the lower tube assembly.
- Install the (2x) M6 x 60 mm button head cap screws to hold the tube foot in
place.
- Install the (4x) M6 washers and (2x) M6 lock nuts, tightening them with the 4 mm Allen
wrench and 10 mm open ended / box wrench.

- Repeat this procedure for the other ramp.