Replacing the Tube Foot

Tools and Equipment

  • Cut-resistant gloves (ANSI Cut Level 3 or EN 388 Level C)
  • 4 mm Allen wrench
  • 10 mm open ended / box wrench

Procedure

  1. Using a 4 mm Allen wrench and an 10 mm open ended / box wrench:
    1. Remove the (4x) M6 washers and (2x) M6 lock nuts securing the (2x) M6 x 60 mm button head cap screws.
    2. Remove the (2x) M6 x 60 mm button head cap screws holding the tube foot in place.
  2. Remove the tube foot from the lower tube assembly.
  3. Slide a new tube foot onto the lower tube assembly.
  4. Install the (2x) M6 x 60 mm button head cap screws to hold the tube foot in place.
  5. Install the (4x) M6 washers and (2x) M6 lock nuts, tightening them with the 4 mm Allen wrench and 10 mm open ended / box wrench.
  6. Repeat this procedure for the other ramp.