Overview

Beginning with Powerwall software version 26.26, Powerwall 3 can be installed with an existing Powerwall 2 system with up to (4) Powerwall 2 units. This installation configuration can be used in the following scenarios:
  • An existing Powerwall 2 customer would like to add more storage to their system
  • Up to two Powerwall 2 units in an existing system require replacement as part of warranty service (see the Installing New Powerwall 3 section in the Powerwall 3 Service Manual)
In this configuration, Powerwall 3 is installed and connected to Powerwall 2 via communication wiring. Important notes about this configuration include:
  • During device setup, Powerwall 3 becomes the Site Controller for the system; Backup Gateway 2 remains the islanding controller and Site meter
  • The Powerwall 3 On/Off switch controls the entire system; each Powerwall 2 switch only controls that unit

Supported System Configurations

Powerwall 3 Existing Powerwall 2 System Remote Energy Metering
Single Powerwall 3 with up to (3) Expansion units Up to (4) Powerwall 2 units with Backup Gateway 2 Tesla Remote Meter

The following existing system configurations are not supported:

Existing Configuration Required Action
More than (4) Powerwall 2 units N/A (not compatible)
Powerwall 2 installed with Backup Gateway 1 and Neurio meter

Replace Backup Gateway 1 with Backup Gateway 2
Replace Neurio meter with Tesla Remote Meter

Powerwall 2 installed with Backup Gateway 2 and Neurio meter Replace Neurio meter with Tesla Remote Meter
Powerwall+ systems Replace all Powerwall+ units with Powerwall 3

System Ratings

Configuration Power Energy
5.8 kW Powerwall 3 7.6 kW Powerwall 3 10 kW Powerwall 3 11.5 kW Powerwall 3
(1) Powerwall 3 (1) Powerwall 2 10.8 kW 12.6 kW 15 kW 16.5 kW 27 kWh
(1) Powerwall 3 with (2) Powerwall 2 units 15.8 kW 17.6 kW 20 kW 21.5 kW 40.5 kWh
(1) Powerwall 3 with (3) Powerwall 2 units 20.8 kW 22.6 kW 25 kW 26.5 kW 54 kWh
(1) Powerwall 3 with (4) Powerwall 2 units 25.8 kW 27.6 kW 30 kW 31.5 kW 67.5 kWh
(1) Powerwall 3 with (3) Expansions* and (4) Powerwall 2 units 25.8 kW 27.6 kW 30 kW 31.5 kW 108 kWh

* Each Expansion unit adds 13.5 kWh of energy, but they do not increase system power. The maximum continuous charge of a system with Expansion units is 8 kW. Actual system power may be limited by state-specific phase imbalance requirements.