Backup Gateway 2 Specifications
Backup Gateway 2 Electrical Specifications
| AC Voltage (Nominal)1 | 230 V (Line-to-Neutral) |
| 400 V (Line-to-Line) | |
| Feed-In Type | Single Phase, Three Phase |
| Grid Frequency | 50-60 Hz |
| Maximum Overcurrent Protection Device | 100 A (single-phase service) |
| 80 A (2- and 3-phase service) | |
| Maximum Input Short Circuit Current | 10 kA |
| Overvoltage Category | Category III |
| AC Meter | Accuracy (+/– 0.2 %) |
| Compatible Earthing Systems2 | TN or TT networks |
| Distribution boards intended to be operated by ordinary persons (DBO) Type | Type B |
| 1230 V (Line-to-Line) is not a supported three-phase configuration. | |
| 2TT earthing networks supported for Gateways with part number 1152100-13-H and higher. | |
Environmental Specifications
| Operating Temperature3 | –20°C to 50°C |
| Operating Humidity (RH) | Up to 100%, condensing |
| Maximum Altitude | 3000 m |
| Ingress Rating | IP55 |
| Environmental Category | Outdoor rated |
| Wet Location Rating | Yes |
| Pollution Degree | PD2 |
| 3 Performance may be de-rated in extreme ambient temperatures | |
Mechanical Specifications
| Dimensions | 584 x 380 x 127 mm |
| Weight | 11.4 kg |
| Breaker space (DIN rail) | Up to nine (9) single pole breakers |
| Mounting Options | Wall mount |
Compliance Information
| Safety | IEC 62109-1, IEC 62053-22, IEC 61439-1, IEC 61439-3 |
| Environmental |
RoHS Directive 2011/65/EU, WEEE Directive 2012/19/EU, Battery Directive 2006/66/EC REACH Regulation EC 1907/2006 |