Backup Gateway 2 Specifications
Backup Gateway 2 Electrical Specifications
AC Voltage (Nominal)1 | 230 V (Line-to-Neutral) |
400 V (Line-to-Line) | |
Feed-In Type | Single Phase, Three Phase |
Grid Frequency | 50-60 Hz |
Maximum Overcurrent Protection Device | 100 A (single-phase service) |
80 A (2- and 3-phase service) | |
Maximum Input Short Circuit Current2 | 16 kA |
Overvoltage Category | Category III |
AC Meter | Accuracy (+/– 0.2 %) |
Compatible Earthing Systems3 | TN or TT networks |
Distribution boards intended to be operated by ordinary persons (DBO) Type | Type B |
1230 V (Line-to-Line) is not a supported three-phase configuration. | |
216 kA rating when installed with current limiting fuse compliant to BS 88.3; 10 kA rating without fuse. | |
3TT earthing networks supported for Gateways with part number 1152100-13-H and higher. |
Environmental Specifications
Operating Temperature4 | –20°C to 50°C |
Operating Humidity (RH) | Up to 100%, condensing |
Maximum Altitude | 3000 m |
Ingress Rating | IP55 |
Environmental Category | Outdoor rated |
Wet Location Rating | Yes |
Pollution Degree | PD2 |
4 Performance may be de-rated in extreme ambient temperatures |
Mechanical Specifications
Dimensions | 584 x 380 x 127 mm |
Weight | 11.4 kg |
Breaker space (DIN rail) | Up to nine (9) single pole breakers |
Mounting Options | Wall mount |
Compliance Information
Safety | IEC 62109-1, IEC 62053-22, IEC 61439-1, IEC 61439-3 |
Environmental |
RoHS Directive 2011/65/EU, WEEE Directive 2012/19/EU, Battery Directive 2006/66/EC REACH Regulation EC 1907/2006 |