Backup Gateway 2 Specifications
Backup Gateway 2 Electrical Specifications
| AC Voltage (Nominal) | 230 V (Line-to-Neutral) |
| 400 V (Line-to-Line) | |
| Feed-In Type | Single Phase, Three Phase |
| Grid Frequency | 50 Hz |
| Maximum Overcurrent Protection Device | 100 A (single-phase service) |
| 80 A (2- and 3-phase service) | |
| Maximum Input Short Circuit Current | 10 kA |
| Overvoltage Category | Category III |
| AC Meter | Revenue accurate (+/– 0.2 %)1 |
| Safety | IEC 61439-1, IEC 61439-3 |
| 1Revenue accurate when using Gateway internal site meter. | |
Note
Refer to circuit breaker datasheet
for rated peak withstand current (Ipk) and associated duration.
Environmental Specifications
| Operating Temperature2 | –20°C to 50°C |
| Operating Humidity (RH) | Up to 100%, condensing |
| Maximum Altitude | 3000 m |
| Ingress Rating | IP55 |
| Environmental Category | Indoor and outdoor rated |
| Wet Location Rating | Yes |
| Pollution Degree | PD2 |
| 2 Performance may be de-rated in extreme ambient temperatures | |
Mechanical Specifications
| Height | 584 mm |
| Width | 380 mm |
| Depth | 127 mm |
| Weight | 11.4 kg |