Powerwall 3 Expansion Specifications

Battery Technical Specifications

Model Number 1807000-xx-y
Nominal Battery Energy 13.5 kWh
Voltage Range 52 - 92 V DC1

1Expansion units are connected in parallel and are not field serviceable.

Compliance Information

Certifications

UL 1973, UL 9540
Meets the unit level performance criteria of UL 9540A

Environmental Specifications

Operating Temperature –20°C to 50°C (–4°F to 122°F)2
Operating Humidity (RH) Up to 100%, condensing
Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non-condensing, State of Energy (SOE): 25% initial
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
Enclosure Rating NEMA 3R
Ingress Rating IP67
Pollution Rating PD3

2Performance may be de-rated at operating temperatures above 40°C (104°F).

Mechanical Specifications

Dimensions 43.5 x 24 x 6.6 in (1105 x 609 x 168 mm)3
Total Weight of Wall-Mounted Unit (includes cover and bracket) 261.2 lb (118.5 kg)
Weight of Powerwall 3 Expansion (no cover or bracket) 242.5 lb (110 kg)
Weight of Glass Front Cover 14.5 lb (6.5 kg)
Weight of Wall Bracket 4.2 lb (1.9 kg)
Weight of Expansion Harness 2 lb (0.9 kg)
Weight of Expansion Unit Accessories 1.5 lb (0.7 kg)
Mounting Options Floor or wall mount
Stacking Capability (Floor Mount Only) Up to (3) Expansion units behind a Powerwall 3
Compatibility with Other Systems Only compatible with Powerwall 3
Connection to Powerwall 3 or Expansions Expansion Harness4
Informational PurposesAn informational icon, calling your attention
Note
See Powerwall 3 Center of Mass for weights of stacked configurations.

3These dimensions include the glass front cover being installed on the Expansion unit.

4The Expansion Harness is a listed component of the UL 9540 certification.