Install Meter Panel and Backup Switch
- De-energize the conductors coming
from the utility meter:
- If there is a disconnect
at the utility meter socket, open it to de-energize the system.NoteDo not leave any loads or solar in the panel upstream of Backup Switch. During system setup, the Backup Switch CTs are automatically configured as Site CTs and cannot be changed. No other CTs should be installed upstream, and no other CTs can be configured as Site. Backup Switch can only be used in whole home backup configurations.
- If there is no disconnect, remove the utility meter as described in Remove the Meter.
- If there is a disconnect
at the utility meter socket, open it to de-energize the system.
- Install the new meter panel
(Tesla P/N 1578042-00-x) per the manufacturer's instructions downstream of the
utility meter as shown above.NoteEnsure the meter panel is oriented correctly, with the line and load sides of the socket positioned correctly.
- Align the Backup Switch with the meter socket and, using a rocking motion, plug
it into place.NoteThe Backup Switch must be fully inserted to ensure the system is grounded.
- Install the sealing ring to
secure the Backup Switch to the meter socket.NoteEnsure the sealing ring is oriented such that the FRONT arrow etched into the ring faces toward Backup Switch, and not the panel. The front wall of the sealing ring is shallower than the rear wall to match the profile of the Backup Switch; thus, the sealing ring cannot be installed if it is not oriented correctly.NoteTesla recommends installing a cable tie or similar locking means on the sealing ring(s) to discourage tampering with Backup Switch.
- Align the jumper cover (Tesla P/N
1833994-00-x / manufacturer P/N Brooks 6572250 JC-4B) with the Backup Switch,
ensuring the jumper cover blades align with the Backup Switch jaws. CAUTIONAttempting to install the jumper cover on the Backup Switch without aligning the blades could result in damage to the Backup Switch.NoteThis is the only jumper cover certified for use when installing Backup Switch in a standalone meter panel. Do not use other jumper cover models.
- Push the jumper cover onto the Backup Switch.
- Install the sealing ring over the
jumper cover.NoteEnsure the sealing ring is oriented such that the FRONT arrow etched into the ring faces toward the jumper cover, and not the panel. The front wall of the sealing ring is shallower than the rear wall to match the profile of the jumper cover; thus, the sealing ring cannot be installed if it is not oriented correctly.NoteTesla recommends installing a cable tie or similar locking means on the sealing ring(s) to discourage tampering with Backup Switch.
Perform a pull test to ensure the Backup Switch feels secure in the meter panel. If the Backup Switch does not feel secure, contact installation support or your supervisor.