MCI and PV String Issues
Test | When to Perform | Required Tools | Pass | Fail |
---|---|---|---|---|
Insulation Resistance (Megger) Test |
Insulation Resistance Tester in 1000 V test mode
![]() |
![]() |
![]() |
|
String True VOC |
Insulation Resistance Tester in 1000 V test mode
![]() |
![]() ![]() |
![]() ![]() |
|
DC Voltage Test (Completed String and Polarity) |
|
Insulation Resistance Tester or Multimeter in DC test mode
|
Single strings: voltage between 10 V and 29 V for Klein testers, voltage of approximately 2 V for Fluke tester | Voltage < 10 V (includes decimal or negative values) |
Combined strings: voltage between 25 V and 48 V for Klein testers, voltage of approximately 4 V for Fluke tester | ||||
MCI Diode Test |
Multimeter in Diode test mode
|
0.25 V ≤ Reading ≤ 0.5 V | Reading < 0.25 V or > 0.5 V | |
MCI Resistance Test |
Insulation Resistance Tester or Multimeter in Resistance test mode
|
Reading > 1 MΩ | Reading < 1 MΩ |