Powershare System Specifications
Electrical Specifications
| Nominal Grid Voltage (Input & Output) | 120/240 VAC Split Phase |
| EVSE Voltage | 240 VAC |
| Grid Frequency | 60 Hz |
| Continuous Neutral Current | 18 A1 |
| Neutral Balancer Apparent Power | 4.32 kVA |
| Maximum Continuous Current | 48 A RMS |
| Maximum Continuous Real Power | 11.5 kW |
| Maximum Continuous Apparent Power | 11.5 kVA |
| Peak Current | 90 A RMS for 0.5 s2 |
| Load Start Capability (1 s) | 110 A LRA |
| EV to EVSE Communication | PLC over Control Pilot Power |
1Powershare Gateway transformer provides neutral balancing
2Values provided for ambient conditions 25°C (77°F).
Compliance Information
| Safety Certifications | UL 9741, UL 1741, UL 1741 CRD for Multi-Mode (MM), UL 916, UL 2594, CSA C22.2#107.1 (Standalone requirements) |
| Grid Performance Certifications | UL 1741 SB |
Note
A Powershare system can be configured as a V2G system with V2H capabilities,
or as a V2H only system.