This manual applies to Wall Connectors identified by part number
1734412-XX-X.
Voltage and Wiring |
Nominal 200-240 V AC single-phase |
Current Output Range |
12 – 48 amps |
Terminal Blocks |
12-4 AWG (4 - 25 mm2), copper |
Supported Conduit Sizing |
¾" (21 mm) default, 1" (27 mm) optional |
Grounding Scheme |
TN |
Frequency |
50/60 Hz |
Cable Length |
24 ft (7.3 m) |
Wall Connector Dimensions |
Height: 13.6 in (345 mm) |
Width: 6.1 in (155 mm) |
Depth: 5.9 in (150 mm) |
Wire Box Bracket Dimensions |
Height: 9.8 in (250 mm) |
Width: 4.7 in (120 mm) |
Depth: 3.5 in (90 mm) |
Weight (including wirebox) |
13lbs (5.7kg) |
Operating Temperature |
-22˚F to 122˚F (-30˚C to 50˚C) |
Storage Temperature |
-40˚F to 185˚F (-40˚C to 85˚C) |
Enclosure Rating |
Type 3R |
Ventilation |
Not required |
Means of Disconnect |
External branch circuit breaker |
Wi-Fi |
2.4 GHz, 802.11b/g/n |
Agency Approvals |
ETL/cETL |
|
Transportation and storage: Ensure that Wall Connector is within storage temperature when
moving, transporting, or storing.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.