2024-05-16

Strip and Land Wiring

  1. Strip insulation from wires ~1/2 in (~13 mm), route through service channel, and land each wire in its correct terminal block.
    Informational PurposesAn informational icon, calling your attention
    Note
    Terminals are bi-directional.
  2. Secure the wiring in the service channel using the included zip tie.
  3. Use a torque driver and the included 4 mm hex bit to torque the terminal screws to 50 in lb (5.6 Nm).
    Informational PurposesAn informational icon, calling your attention
    Note
    When installing Wall Connector in a split phase electrical system, use Line-to-Line instead of Line-to-Neutral.