Close Equipment and Turn System On
- Before closing any installed hardware, take photos of the completed wiring in the Wall Connector, Powershare Gateway, and main distribution board.
- Ensure that all conduit junctions and cable entry points are secure and properly sealed.
- Install the Powershare Gateway dead front cover and secure it firmly with the original screw. Mount the Powershare Gateway door, and latch it shut.
-
If the system includes solar in
the backup circuit, install the following label near the customer's main breaker
in their electrical panel:
CAUTIONIt is critical that this label be installed, and that the customer understands they must turn their solar breaker(s) OFF before attempting to test Powershare functionality by turning the main breaker off. If the main breaker is turned off while solar breaker(s) are still ON, the customer may experience damage to their home loads.
-
Attach Wall Connector to the wirebox:
-
Switch on the circuit breaker
for the Powershare Gateway and Wall
Connector.
WarningUpon powering on the Powershare Gateway and Wall Connector system, allow it to boot up undisturbed for at least one minute. Do not power cycle or reset the Powershare Gateway during this time, as the boot sequence must be completed for the software to operate properly.NoteThe door is opened by applying pressure inward and depressing the latch on the right side of the enclosure.