Check Connected Devices
Select
to check the connected devices. The Devices page must display all devices; if a device does not appear, check the communication wiring for errors.Backup Switch / Backup Gateway 2 Device Page Overview
The Backup Switch / Backup Gateway 2 acts as the Islanding Contactor; this page provides a more direct view of the island state of the system and the state of the micro-grid.
1 | Contactor State | On Grid / Off Grid |
2 | Vitals |
Grid State:
|
Line voltage 1 | ||
Frequency 1 |
1 When the system is off-grid, the micro-grid (load-side) values are shown as the voltage / frequency can be different on the grid and home side of the island.
Powerwall+ Device Page Overview
1 | Vitals | Solar generation, battery charge level, charge/discharge power |
2 | Inverter State | Disable / DC Only / Enable |
3 | MPPT | DC voltage and current for each active MPPT |
4 | Battery State | State, phase and line voltage, frequency |
Powerwall 2 Device Page Overview
1 | Vitals | Battery charge level, charge/discharge power |
2 | Battery State | State, phase and line voltage, frequency |
Tesla Solar Inverter Device Page Overview
1 | Vitals | Solar generation |
2 | Inverter State | Disable / DC Only / Enable |
3 | AC Vitals | AC voltage vitals |
4 | MPPT | DC voltage and current for each active MPPT |